skip to Main Content

Plug-in Power Adapter, 24 V / 90 W

Class 2 

Save

Save

Save

Plug In Power Adapter 24 V, 90 W
Plug In Power Adapter 24 V, 90 W

Plug-in Power Adapter, 24 V / 90 W

About

A 24 V Plug-in Power Supply that is designed for compatibility with DLC LED lighting products. Ideal for retail and architectural applications.

Save

Save

Save

    Class 2

Save

Save

Save

FEATURES
Universal AC input / full range
89% – 90% efficiency
Built-in active PFC function
Class 2 Power Supply
Protections: Short circuit / Over current / Over voltage / Over temperature
Fanless design, cooling by free air convection
No load power consumption < 0.15 W
UL listed, suitable for dry and damp environments
Technical Information
Input
Voltage Range 190 ~ 264 VAC / 127 ~ 370 VAC
Frequency Range47 ~ 63 Hz
Power FactorPF > 0.98 / 115 VAC; PF > 0.96 / 230 VAC at full load
Total Harmonic Distortion< 20% when output loading ≧ 60% at 115 VAC / 230 VAC
Efficiency115 VAC: 89%; 230 VAC: 90%
AC Current0.95 A / 115 VAC; 0.5 A / 230 VAC
Inrush CurrentCold start: 30 A (twidth = 550 ÎĽs measured at 50% Ipeak) at 115 VAC
Cold start: 60 A (twidth = 550 ÎĽs measured at 50% Ipeak) at 230 VAC
Max. Number of PSUs / 16 A Circuit Breaker3 units (type B circuit breaker)
6 units (type C circuit breaker) at 230 VAC
Leakage Current<0.125 mA / 120 VAC <0.25 mA / 240 VAC
Output
DC Voltage24 VDC
Constant Current Region14.4 ~ 24 V
Rated Current3.75 A
Rated Power90 W
Ripple and Noise 2150 mVp-p
Voltage Tolerance 3± 3%
Line Regulation± 0.5%
Load Regulation± 0.5%
Setup, Rise Time
4
500 ms, 80 ms at 95% load 115 VAC / 230 VAC
Hold Up Time (Typ.)16 ms at full load 115 VAC / 230 VAC
Protection
Over Current 95% ~ 108% Protection type: Constant current limiting, recovers automatically after fault condition is removed
Short Circuit Hiccup mode, recovers automatically after fault condition is removed
Over Voltage 28 V ~ 34 V Protection type: shut down o/p voltage, re-power on to remove
Over Temperature Shut down o/p voltage, re-power on to recover
Environment
Operating Temperature -40 °C ~ +70 °C (refer to "derating curve")
Storage Temperature-40 °C ~ +80 °C
Operating Humidity20% ~ 95% RH non-condensing
Storage Humidity10% ~ 95% RH
Temp. Coefficient± 0.03% / °C (0 ~ 50 °C)
Vibration10 ~ 500 Hz, 5G 12 minutes / 1 cycle, period for 72 minutes each along X, Y, Z axes
Withstanding Voltage I/P-O/P: 3.75K VAC
Isolation ResistanceI/P-O/P:100M Ohms / 500 VDC / 25°C / 70% RH
EMC EmissionCompliance to FCC Part 15
Certifications UL8750 listed, CSA C22.2 No. 250.13-12 IP67 (for main body) approved
Dimensions6 23/32" (171 mm) L x 2 15/32" (63 mm) W x 1 15/32" (37.5 mm) H
Additional
Mean Time Before Failure>292 800 hours MIL-HDBK-217F (25 °C)
Packaging0.83 Kg; 16 pcs / 14.3 Kg / 1.01 ft3

Top View

Plug-In Power Adapter 24 V / 90 W Top View

Profile View

Plug-In Power Adapter 24 V / 90 W Profile View



Electrical Components

Plug-In Power Adapter 24 V / 90 W Electrical Components




Derating Curve

Plug-In Power Adapter 24 V / 90 W Derating Curve




Static CharacteristicsPlug-In Power Adapter 24 V / 90 W Static Characteristics




Notes:

1. All parameters not specially mentioned are measured at 230 VAC input, rated load and 25 °C of ambient temperature
2. Ripple & noise are measured at 20 MHz of bandwidth by using a 12? twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor
3. Tolerance: Includes set up tolerance, line regulation and load regulation
4. Length of set up time is measured at cold first start. Turning on / off the power supply may lead to increase of set up time

Order Information